Toshiba G9000 Floor UPS
-
Mapped Fields:
Inlet pole: voltage, current, active power Circuit: phase& power
- Traps: Yes
- Created by: Tim Paulson
-
Trap mappings:
The UPS has switched to battery backup power, UPS test has been completed, UPS has returned to Normal Power, Warning: Battery Low Voltage, Battery is no longer Low Voltage, UPS contains depleted batteries, UPS no longer contains depleted batteries, UPS Battery Overheated, UPS Battery no longer Overheated, Fault:Battery Voltage Abnormal, Battery Voltage no longer Abnormal, Fault:UPS Overheat, heatsinks temperature exceeds thermal settings. Contact your Toshiba authorized service center for examination, UPS Overheat, heatsinks temperature no longer exceeds thermal setting, Power Failure, Power Failure Cleared, Fault:UPS Overload (OL), the output load exceeds the rated current. Decrease load, UPS no longer Overloaded, Warning:The inverter output load % is greater than the user defined overload set point (default:110%), The inverter output load % is no longer greater then the user defined set point, UPS on Bypass, UPS no longer on Bypass, UPS Output is OFF, UPS Output is On, Fault:DC Overcurrent (DCOC). Contact your Toshiba authorized service center for examination, DC is no longer Overcurrent (DCOC), Fault:DC Overvoltage (DCOV). Contact your Toshiba authorized service center for examination, DC no longer Overvoltage, Fault:DC Undervoltage (DCUV). Contact your Toshiba authorized service center for examination, DC no longer Undervoltage, Fault:DC Unbalance. Contact your Toshiba authorized service center for examination, DC no longer Unbalance, Fault:Output Undervoltage. Contact your Toshiba authorized service center for examination, Output no longer Undervoltage, Fault:Output Overvoltage (VLOV). Contact your Toshiba authorized service center for examination, Output no longer Overvoltage (VLOV), Fault:UPS Inverter Overload, short time over-current has been detected during On-Line operation. Decrease Load, UPS no longer Inverter Overloaded, Fault:Inverter Overcurrent. Contact your Toshiba authorized service center for examination, & Inverter no longer Overcurrent
- Trap clearing: No
- Plugin Type: custom
- Classification: SNMP
- Tested PowerIQ Version: 5.2
- Certified: Yes
- Certified By: Gary Elango
- Date Created: Friday, 07 October 2016
- License: 1
Download attachments:
- toshiba_ups_g9000_750kva_remoteye_custom.zip (89 Downloads)
http://addons.sunbirddcim.com/index.php/plugins-top/item/29-toshiba-g9000-floor-ups#sigProId26e9497238