Toshiba T90S3S16KS6XSN2 Floor UPS

  • Mapped Fields:

    Inlet Pole: Voltage, Current, and Active Power. Circuit Pole: Voltage, Current, and Phase. Battery: Voltage, Status, Seconds On, Current, Capacity Percentage, and Runtime Remaining. Circuit: Active Power, Name, and Power Factor. Inlet: Rated Amps. UPS Output: Source and Load Percentage. 

  • Traps: Yes
  • Created by: Gary Elango
  • Trap mappings:

    The UPS has switched to battery backup power, UPS test has been completed, UPS has returned to Normal Power, Warning: Battery Low Voltage, Battery is no longer Low Voltage, UPS contains depleted batteries, UPS no longer contains depleted batteries, UPS Battery Overheated, UPS Battery no longer Overheated, Fault:Battery Voltage Abnormal, Battery Voltage no longer Abnormal, Fault:UPS Overheat, heatsinks temperature exceeds thermal settings. Contact your Toshiba authorized service center for examination, UPS Overheat, heatsinks temperature no longer exceeds thermal setting, Power Failure, Power Failure Cleared, Fault:UPS Overload (OL), the output load exceeds the rated current. Decrease load, UPS no longer Overloaded, Warning:The inverter output load % is greater than the user defined overload set point (default:110%), The inverter output load % is no longer greater then the user defined set point, UPS on Bypass, UPS no longer on Bypass, UPS Output is OFF, UPS Output is On, Fault:DC Overcurrent (DCOC). Contact your Toshiba authorized service center for examination, DC is no longer Overcurrent (DCOC), Fault:DC Overvoltage (DCOV). Contact your Toshiba authorized service center for examination, DC no longer Overvoltage, Fault:DC Undervoltage (DCUV). Contact your Toshiba authorized service center for examination, DC no longer Undervoltage, Fault:DC Unbalance. Contact your Toshiba authorized service center for examination, DC no longer Unbalance, Fault:Output Undervoltage. Contact your Toshiba authorized service center for examination, Output no longer Undervoltage, Fault:Output Overvoltage (VLOV). Contact your Toshiba authorized service center for examination, Output no longer Overvoltage (VLOV), Fault:UPS Inverter Overload, short time over-current has been detected during On-Line operation. Decrease Load, UPS no longer Inverter Overloaded, Fault:Inverter Overcurrent. Contact your Toshiba authorized service center for examination, & Inverter no longer Overcurrent

  • Trap clearing: No
  • Plugin Type: custom
  • Classification: SNMP
  • Tested PowerIQ Version: 9.x
  • Certified: Yes
  • Certified By: Gary Elango
  • Date Created: Wednesday, 06 March 2024
  • License: 1

Download attachments:

Read 376 times