Vertiv Liebert GXT5 3KL630RT2UXL Rack UPS

  • Mapped Fields:

    Inlet Pole: Index, Voltage, & Current. Outlet: Active Power, Apparent Power, and Power Factor. Outlet Pole: Index, Current, & Voltage. Temperature Sensor: Name & Value. Battery: Voltage, Runtime Remaining, Capacity Percentage, Status, Seconds On, and Current. UPS Output: Source and Load Percentage. UPS Output Pole: Index.

  • Traps: Yes
  • Created by: Gary Elango
  • Trap mappings:

    One or more batteries have been determined to require replacement, One or more batteries have no longer been determined to require replacement, The Bypass is out of tolerance, The Bypass is no longer out of tolerance, The output of the UPS is in the off state, The output of the UPS is in the on state, A general fault in the UPS has been detected, A general fault in the UPS has no longer been detected, The result of the last diagnostic test indicates a failure, The result of the last diagnostic test no longer indicates a failure, The UPS is drawing power from the batteries, The UPS is no longer drawing power from the batteries, A test is in progress, The remaining battery run-time is low, The remaining battery run-time is no longer low, A temperature is out of tolerance, A temperature is no longer out of tolerance, An input condition is out of tolerance, An input condition is no longer out of tolerance, An output condition (other than OutputOverload) is out of tolerance, An output condition is no longer out of tolerance, The output load exceeds the UPS output capacity, The output load no longer exceeds the UPS output capacity, The Bypass is presently engaged on the UPS, The Bypass is no longer engaged on the UPS, The system has detected that there is no power being supplied to the\nload, The system has detected that there is power being supplied to the load, The battery's remaining charge is less than or equal to the configured low threshold, The battery's remaining charge is no longer less than or equal to the configured low threshold, The system has detected a battery self-test failure, The system has no longer detected a battery self-test failure, The system has transferred to bypass, The system his no longer on bypass, The system has detected an output overload condition, The system has no longer detected an output overload condition, The system or a component of the system has detected an over temperature condition, The system or a component of the system has no longer detected an over temperature condition, The system has detected a utility failure, The system has no longer detected a utility failure, The system is performing a battery test at this time, The system load is being supported by the battery, The system load is no longer being supported by the battery, The system has detected the batteries are due to be replaced, The system has no longer detected the batteries are due to be replaced, The system is in a shutdown pending condition, The system has detected the bypass voltage is unqualified, The system has no longer detected the bypass voltage is unqualified, System output is off - 'Emergency Power Off (EPO) - latched' requires manual reset, System output is on, Inverter failure - inverter output is off, Inverter Failure Cleared, Rectifier failure - rectifier is off, Rectifier Failure Cleared, System fan failure - one or more fans have failed, System Fan Failure Cleared, The maintenance bypass breaker is closed, The maintenance bypass breaker is open, Charger Failure - Charger is off, Charger Failure Cleared, The neutral/ground conductors on the input wiring are not properly bonded, or the line/neutral conductors have been swapped, The neutral/ground conductors on the input wiring are now properly bonded, or the line/neutral conductors have been swapped, A failure has occurred in the battery discharge circuit, A failure has been corrected in the battery discharge circuit, The RMS input current has reached the input current limit threshold, The RMS input current has no longer reached the input current limit threshold, The system detected a voltage on the bypass when none was expected, The system has no longer detected a voltage on the bypass when none was expected, A battery temperature sensor is reporting a value above a threshold, A battery temperature sensor is no longer reporting a value above a threshold, The output power is supplied by the inverter, The output power is no longer being supplied by the inverter, The control has detected a communication failure of a component on the internal communication bus, he control has no longer detected a communication failure of a component on the internal communication bus, System Input Currents are Imbalanced, System Input Currents are no longer Imbalanced, A fault has been detected in the system output, A fault has no longer been detected in the system output

  • Trap clearing: Yes
  • Plugin Type: structured
  • Classification: SNMP
  • Tested PowerIQ Version: 9.x
  • Certified: Yes
  • Certified By: Gary Elango
  • Date Created: Wednesday, 13 March 2024
  • License: 1

Download attachments:

Read 357 times