Chatsworth RIM 750 Meter

  • Mapped Fields:

    Binary Sensor (Leak Detection): On/Off & Name. External Sensors: Value, Type, & Name.

  • Traps: Yes
  • Created by: Erin Lee
  • Trap mappings:

    A Digital Input 1 Alarm trap indicates that digital input 1 has either opened or closed to cause an alarm, A Digital Input 2 Alarm trap indicates that digital input 2 has either opened or closed to cause an alarm, A Digital Input 3 Alarm trap indicates that digital input 3 has either opened or closed to cause an alarm, A Digital Input 4 Alarm trap indicates that digital input 4 has either opened or closed to cause an alarm, A Digital Input 5 Alarm trap indicates that digital input 5 has either opened or closed to cause an alarm, A Digital Input 6 Alarm trap indicates that digital input 6 has either opened or closed to cause an alarm, A Digital Input 7 Alarm trap indicates that digital input 7 has either opened or closed to cause an alarm, A Digital Input 8 Alarm trap indicates that digital input 8 has either opened or closed to cause an alarm, A Digital Input 1 Normal trap indicates that digital input 1 has returned to normal, A Digital Input 2 Normal trap indicates that digital input 2 has returned to normal, A Digital Input 3 Normal trap indicates that digital input 3 has returned to normal, A Digital Input 4 Normal trap indicates that digital input 4 has returned to normal, A Digital Input 5 Normal trap indicates that digital input 5 has returned to normal, A Digital Input 6 Normal trap indicates that digital input 6 has returned to normal, A Digital Input 7 Normal trap indicates that digital input 7 has returned to normal, A Digital Input 8 Normal trap indicates that digital input 8 has returned to normal, A Digital Input 1 Opened trap indicates that digital input 1 has just been Opened, A Digital Input 2 Opened trap indicates that digital input 2 has just been Opened, A Digital Input 3 Opened trap indicates that digital input 3 has just been Opened, A Digital Input 4 Opened trap indicates that digital input 4 has just been Opened, A Digital Input 5 Opened trap indicates that digital input 5 has just been Opened, A Digital Input 6 Opened trap indicates that digital input 6 has just been Opened, A Digital Input 7 Opened trap indicates that digital input 7 has just been Opened, A Digital Input 8 Opened trap indicates that digital input 8 has just been Opened, A Digital Input 1 Closed trap indicates that digital input 1 has just been Closed, A Digital Input 2 Closed trap indicates that digital input 2 has just been Closed, A Digital Input 3 Closed trap indicates that digital input 3 has just been Closed, A Digital Input 4 Closed trap indicates that digital input 4 has just been Closed, A Digital Input 5 Closed trap indicates that digital input 5 has just been Closed, A Digital Input 6 Closed trap indicates that digital input 6 has just been Closed, A Digital Input 7 Closed trap indicates that digital input 7 has just been Closed, A Digital Input 8 Closed trap indicates that digital input 8 has just been Closed, A leakDetected trap indicates a leak has been detected on the cable, A leakCleared trap indicates a leak is no longer detected, A leakCableBreak trap indicates a leak cable has been disconnected or broken, A leakCableConnected trap indicates a leak cable has been connected or repaired, A Sensor 1 Temperature Alarm trap indicates the temperature has exceeded the given range, A Sensor 2 Temperature Alarm trap indicates the temperature has exceeded the given range, A Sensor 3 Temperature Alarm trap indicates the temperature has exceeded the given range, A Sensor 4 Temperature Alarm trap indicates the temperature has exceeded the given range, A Sensor 1 Temperature Normal trap indicates the temperature has returned to the given range, A Sensor 2 Temperature Normal trap indicates the temperature has returned to the given range, A Sensor 3 Temperature Normal trap indicates the temperature has returned to the given range, A Sensor 4 Temperature Normal trap indicates the temperature has returned to the given range, A Sensor 1 Humidity Alarm trap indicates the humidity is out of range, A Sensor 2 Humidity Alarm trap indicates the humidity is out of range, A Sensor 3 Humidity Alarm trap indicates the humidity is out of range, A Sensor 4 Humidity Alarm trap indicates the humidity is out of range, A Relay 1 Closed trap indicates the relay has been energized (Closed), A Relay 1 Opened trap indicates the relay has been energized (Opened), A f200Alarm trap indicates the F200 has at least one alarm, A f200Normal trap indicates the F200 has returned to normal, ther are no alarms,

  • Trap clearing: No
  • Plugin Type: custom
  • Classification: SNMP
  • Tested PowerIQ Version: 9.x
  • Certified: Yes
  • Certified By: Erin Lee
  • Date Created: Thursday, 28 March 2024
  • License: 1

Download attachments:

Read 335 times