The following devices are supported natively or "out of the box" in Power IQ.

For a list of events for supported devices, see the Power IQ online help or user guide available on the Sunbird support portal.

 
Vendor Product Type Description Model Supported Product Firmware Proxy Index
Required even
when not daisy chained
MIB
APC (Schneider) Rack PDU Metered Rack PDU Series 78XX v3.9.3 RPDU   PowerNet 4.5.2
APC (Schneider) Rack PDU Switched Rack PDU Series 79XX

v3.0 NMC3

v7.1.3

v7.0.8 RPDU2

v2.5.0.6 RPDU

  PowerNet 4.5.2
APC (Schneider) Rack PDU Switched and Metered (Note: The standalone and daisy chained PDUs are both supported.) 8XXX 

v3.0 NMC3

v7.1.3 RPDU2

v2.5.0.6 RPDU

  PowerNet 4.5.2
APC (Schneider) Rack PDU Switched Rack PDU Series (Note: The standalone and daisy chained PDUs are both supported.) 9XXX

v3.0 NMC3

v2.5.0.6 RPDU

  PowerNet 4.5.2
APC (Schneider) Rack PDU Switched and Metered (Note: The standalone and daisy chained PDUs are both supported.) 10XXX 

v2.0.6.7

v2.0.6.5 NetShelter

  apc_cpdu_V1_4
APC (Schneider) Netbotz Probe All models All f/w    
APC (Schneider) UPS Uninterruptible power supply backUPS, Smart-UPS series, Smart-UPS X series, Floor UPS families, GVSUPS100KG, Symmetra LX series 520.2000.D Symmetra   PowerNet 4.5.2
Aphel (Eaton) PDU Single phase meter DBQ10285/3     Aphel_Genesis
Avocent (Vertiv) Rack PDU Rack PDU Series PM1000, PM2000, PM3000 1.3.0   Avocent-PM-MIB_2.0.1
Baytech Rack PDU RPC Series RPC Series with Ethernet Access; standalone or with a DC controller F 1.09   Baytech_UNIV_4131
Baytech Rack PDU   MRP and MMP Series     Baytech_UNIV_4131
Chatsworth PDU

P3 series

P4 series

P6 series

E1 series

All take the form PX-xxxxx-xxx   Standalone can be added with no proxy, when in a secure array uses the MAC address as proxy index CPI-UNITY-MIB-01_10_2023
Chatsworth PDU 36 outlet, 3 phase, 60 amp, Vertical 24 outlet

TS1009368

TS1009814

TS1009942

5.3.1050 and newer   CPI-UNITY-MIB-01_10_2023
Control Solutions, Inc. Gateway Protocol Inverter Babel Buster SPX      
CyberSwitching Rack PDU Smart Dualcom series DC1620V, DC1630ViC B, DC1640V, DC440i, DC440L, DC460L, DC820, DC830i, DC840    

CYBERSWITCHING-COMMON

CYBERSWITCHING-DUALCOM

CYBERSWITCHING-EPOWER

CYBERSWITCHING-PM8
Cyclades Rack PDU Cyclades PM PDU series Cyclades PM PDU series products are connected to Cyclades ACS Console Server (via SNMP)   Required, the first digit of the proxy index is the serial port that the PDU is attached to the ACS server and the second digit is the position in the chain the PDU is in

Cyclades-ACS-V3.3-MIB-sw0103002
Eaton Rack PDU ePDU Eaton standard Density & High Density PWXXX series models   (G3, eAM004) – default 0 EATON-EPDU-MIB
Geist (Vertiv) Rack PDU Ethernet Metered PDUs GM Series EM40/GM1 5-120, EM40/GM1 5-80 1.46   Geist_EM_v2.08
Geist (Vertiv)     EM 8/GM6, EM 8/GM 3, EM 40/GM 22, EM 8/G M2, EM 8/GM 1     Geist_EM_v2.08
HP Rack PDU AF Series AF 5XXX, 9XXX, 370962-D7 1    

HP_cpqhost

HP_cpqpower_1.80

HP Rack PDU Rack PDUs with HP power strips that use the PDU2 section of the HP-Compaq Power MIB HP 8.6kVA 208V 3Ph 21out NA/JP mPDU    

HP_cpqhost

HP_cpqpower_1.80
Knurr (Vertiv) Rack PDU DI-STRIP® Knuerr PDU-Ethernet system   Required, must be greater than 0 Knuerr-PDU-ETH-MIB_20131113
Liebert (Vertiv) Rack PDU   MPX, MPH, & MPH2 Series   Required, must be greater than 0  
Liebert (Vertiv) UPS Uninterruptible power supply NPower 30 - 130 kVA UPS Systems V 1 .27  

LIEBERT_GP_AGENT

LIEBERT_GP_AGENT21

LIEBERT_GP_COND

LIEBERT_GP_CONTROLLER

LIEBERT_GP_ENV

LIEBERT_GP_FLEXIBLE

LIEBERT_GP_FLEXIBLE_COND

LIEBERT_GP_NOTIFY

LIEBERT_GP_PDU

LIEBERT_GP_POWER

LIEBERT_GP_REG

LIEBERT_GP_REGISTRATION

LIEBERT_GP_SYSTEM
Liebert (Vertiv) FDC Power Distribution Cabinet Each FDC can have up to 4 panels. Each panel in turn supports up to 42 circuits     Required, must be greater than 0

LIEBERT_GP_AGENT

LIEBERT_GP_AGENT21

LIEBERT_GP_COND

LIEBERT_GP_CONTROLLER

LIEBERT_GP_ENV

LIEBERT_GP_FLEXIBLE

LIEBERT_GP_FLEXIBLE_COND

LIEBERT_GP_NOTIFY

LIEBERT_GP_PDU

LIEBERT_GP_POWER

LIEBERT_GP_REG

LIEBERT_GP_REGISTRATION

LIEBERT_GP_SYSTEM
MRV Console Server LX Series LX4000T   Required, must be greater than 0

MRV_LX System

MRV_LX_Character

nVent Rack PDU Only PDU’s with IP dongle firmware IPG-02-FW-v07 PDU’s with IP dongle W meter firmware 1B-v14W or above   RackPower-MIB-Q418V2
Network Technologies Incorporated PDU Sensor Aggregator Enviromux   Optional, if no proxy index specified the plugin  assigns a value of 1 NTI_Environmux_sems-16-v1.11-1
MRV Rack PDU LX Series LX-5250, LX-5210, LX-4800 5.3.2 Required, must be greater than 0  
Raritan (Legrand) Rack PDU Hybrid and Classic PDUs EM40/PM1 5-120, EM40/PM1 5-80, EM 8/PM 6, EM 8/PM 3, EM 40/PM 22, EM 8/PM 2, EM 8/PM 1 1.46 Optional, if no proxy index specified,  the plugin will assign a value of 1. If specified cannot be 0.If a proxy index is given it will discover that one specifically and all children. RaritanPDU_1.6
Raritan (Legrand) Rack PDU PX Series All models in each CDU series All firmware versions Optional, defaults to 1 if no proxy index is provided. RaritanPDU_1.6
RT Systems PDU Sensor Aggregator TM2, TM3     RTSYS-MIB

TM2-MIB

TM3-MIB
Rittal (Friedhelm Loh Group) Rack PDU Metered Power System Module & CMC-TC Processing Unit II

M/V4x and M/V5x models

CMCIII-PU

RSA04_PSM

CMCIII-GAT

  CMC-TU – 0 or greater, in PIQ 5.1.2 RITTAL-CMC-III-CAPABILITY-MIB
Schleifenbauer Rack PDU  

SGOSDIM3301-002

SAPRHIN3101-001

SMIKDIB1103-001

SSENHIB3101-002

SSCHDIB1104-001

SPSPHIN1104-001

SPSPHIN1107-001

  Optional, if no proxy index specified, the plugin assigns a value of 1

SCHLEIFENBAUER-DATABUS

SCHLEIFENBAUER-PRODUCTS

SCHLEIFENBAUER-SMI

SPGW_MIB

ServerTech (Legrand) Rack PDU POPS, Switched, and Smart series, CDUs and Sentry3 and 4 All models in each CDU series

6.0, 7.0, 8.0

(Recommended v7.0m firmware or newer)

Optional, if no proxy index specified, the plugin assigns a value of 1. If specified cannot be 0. If a proxy index is given it will discover that one specifically and all children.

Sentry3_20160125

Sentry4_20160921

Panduit/Unite/
Sinetica
Rack PDU Hawk-I Controller Unit & PDUs     Required, must be greater than 0  
Tripp Lite Rack PDU  

PDU3VN

PDU3VSR

PDUMH20HVATNET

     
Starline (Legrand) PDU / Rack PDU Overhead Power Distribution

M40 series

V40 series

M50 series

V50 series

Complete model list here

4.07 M type meters will be discovered using a proxy index of 1. Null proxy index 0 will not be used

V type meters will take a proxy index of 1 up to the maximum outlet count.
Proxy Index 1 will represent Outlet 1
Proxy Index 2 will represent Outlet 2, etc

Read and Write community strings must be the same
UEC_v27