Standard Plugins
Standard Plugins
The following devices are supported natively or "out of the box" in Power IQ.
For a list of events for supported devices, see the Power IQ online help or user guide available on the Sunbird Support Portal.
Vendor | Product Type | Description | Model | Supported Firmware | MIB | Proxy Index* |
Aphel (Eaton) | PDU | Single phase meter | DBQ10285/3 | Aphel_Genesis | ||
Avocent (Vertiv) | Rack PDU | Rack PDU Series | PM1000, PM2000, PM3000 | 1.3.0 | Avocent-PM-MIB_2.0.1 | |
Baytech | Rack PDU | RPC Series | RPC Series with Ethernet Access; standalone or with a DC controller | F 1.09 | Baytech_UNIV_4131 | |
Baytech | Rack PDU | MRP and MMP Series | Baytech_UNIV_4131 | |||
Chatsworth | PDU | P3 series, P4 series, P6 series, E1 series | All take the form PX-xxxxx-xxx | CPI-UNITY-MIB-01_10_2023 | Standalone can be added with no proxy, when in a secure array uses the MAC address as proxy index | |
Chatsworth | PDU | 36 outlet, 3 phase, 60 amp, Vertical 24 outlet | TS1009368, TS1009814, TS1009942 | 5.3.1050 and newer | CPI-UNITY-MIB-01_10_2023 | |
Control Solutions, Inc. | Gateway | Protocol Inverter | Babel Buster SPX | |||
CyberSwitching | Rack PDU | Smart Dualcom series | DC1620V, DC1630ViC B, DC1640V, DC440i, DC440L, DC460L, DC820, DC830i, DC840 | CYBERSWITCHING-COMMON, CYBERSWITCHING-DUALCOM, CYBERSWITCHING-EPOWER, CYBERSWITCHING-PM8 | ||
Cyclades | Rack PDU | Cyclades PM PDU series | Cyclades PM PDU series products are connected to Cyclades ACS Console Server (via SNMP) | Cyclades-ACS-V3.3-MIB-sw0103002 | Required, the first digit of the proxy index is the serial port that the PDU is attached to the ACS server and the second digit is the position in the chain the PDU is in | |
Eaton | Rack PDU | ePDU | Eaton standard Density & High Density PWXXX series models | EATON-EPDU-MIB | (G3, eAM004) – default 0 | |
Geist (Vertiv) | Rack PDU | Ethernet Metered PDUs GM Series | EM40/GM1 5-120, EM40/GM1 5-80 | 1.46 | Geist_EM_v2.08 | |
Geist (Vertiv) | EM 8/GM6, EM 8/GM 3, EM 40/GM 22, EM 8/G M2, EM 8/GM 1 | Geist_EM_v2.08 | ||||
HP | Rack PDU | AF Series | AF 5XXX, 9XXX, 370962-D7 1 | HP_cpqhost, HP_cpqpower_1.80 | ||
HP | Rack PDU | Rack PDUs with HP power strips that use the PDU2 section of the HP-Compaq Power MIB | HP 8.6kVA 208V 3Ph 21out NA/JP mPDU | HP_cpqhost, HP_cpqpower_1.80 | ||
Knurr (Vertiv) | Rack PDU | DI-STRIP® | Knuerr PDU-Ethernet system | Knuerr-PDU-ETH-MIB_20131113 | Required, must be greater than 0 | |
Liebert (Vertiv) | Rack PDU | MPX, MPH, & MPH2 Series | Required, must be greater than 0 | |||
Liebert (Vertiv) | UPS | Uninterruptible power supply | NPower 30 - 130 kVA UPS Systems | V 1 .27 |
LIEBERT_GP_AGENT, LIEBERT_GP_AGENT21, LIEBERT_GP_COND, LIEBERT_GP_CONTROLLER, LIEBERT_GP_ENV, LIEBERT_GP_FLEXIBLE, LIEBERT_GP_FLEXIBLE_COND, LIEBERT_GP_NOTIFY, LIEBERT_GP_PDU, LIEBERT_GP_POWERLIEBERT_GP_REGLIEBERT_GP_REGISTRATIONLIEBERT_GP_SYSTEM |
|
Liebert (Vertiv) | FDC Power Distribution Cabinet | Each FDC can have up to 4 panels. Each panel in turn supports up to 42 circuits |
LIEBERT_GP_AGENT, LIEBERT_GP_AGENT21, LIEBERT_GP_COND, LIEBERT_GP_CONTROLLER, LIEBERT_GP_ENV, LIEBERT_GP_FLEXIBLE, LIEBERT_GP_FLEXIBLE_COND, LIEBERT_GP_NOTIFY, LIEBERT_GP_PDU, LIEBERT_GP_POWERLIEBERT_GP_REGLIEBERT_GP_REGISTRATIONLIEBERT_GP_SYSTEM |
Required, must be greater than 0 | ||
MRV | Console Server | LX Series | LX4000T | MRV_LX System, MRV_LX_Character | Required, must be greater than 0 | |
nVent | Rack PDU | Only PDU’s with IP dongle firmware IPG-02-FW-v07 | PDU’s with IP dongle | W meter firmware 1B-v14W or above | RackPower-MIB-Q418V2 | |
Network Technologies Incorporated | PDU | Sensor Aggregator | Enviromux | NTI_Environmux_sems-16-v1.11-1 | Optional, if no proxy index specified the plugin assigns a value of 1 | |
MRV | Rack PDU | LX Series | LX-5250, LX-5210, LX-4800 | 5.3.2 | Required, must be greater than 0 | |
Raritan (Legrand) | Rack PDU | Hybrid and Classic PDUs | EM40/PM1 5-120, EM40/PM1 5-80, EM 8/PM 6, EM 8/PM 3, EM 40/PM 22, EM 8/PM 2, EM 8/PM 1 | 1.46 | RaritanPDU_1.6 | Optional, if no proxy index specified, the plugin will assign a value of 1. If specified cannot be 0.If a proxy index is given it will discover that one specifically and all children. |
Raritan (Legrand) | Rack PDU | PX Series | All models in each CDU series | All firmware versions | RaritanPDU_1.6 | Optional, defaults to 1 if no proxy index is provided. |
RT Systems | PDU | Sensor Aggregator | TM2, TM3 | RTSYS-MIBTM2-MIBTM3-MIB | ||
Rittal (Friedhelm Loh Group) | Rack PDU | Metered Power System Module & CMC-TC Processing Unit II | M/V4x and M/V5x models, CMCIII-PU, RSA04_PSM, CMCIII-GAT | RITTAL-CMC-III-CAPABILITY-MIB | CMC-TU – 0 or greater, in PIQ 5.1.2 | |
Schleifenbauer | Rack PDU | SGOSDIM3301-002, SAPRHIN3101-001, SMIKDIB1103-001, SSENHIB3101-002, SSCHDIB1104-001k, SPSPHIN1104-001, SPSPHIN1107-001 | SCHLEIFENBAUER-DATABUS, SCHLEIFENBAUER-PRODUCTS, SCHLEIFENBAUER-SMI, SPGW_MIB | Optional, if no proxy index specified, the plugin assigns a value of 1 | ||
Schneider Electric | Rack PDU | Metered Rack PDU Series | 78XX | v3.9.3 RPDU | PowerNet 4.5.2 | |
Schneider Electric | Rack PDU | Switched Rack PDU Series | 79XX | v3.0 NMC3, v7.1.3 ,v7.0.8 RPDU2 ,v2.5.0.6 RPDU | PowerNet 4.5.2 | |
Schneider Electric | Rack PDU | Switched and Metered (Note: The standalone and daisy chained PDUs are both supported.) | 8XXX | v3.0 NMC3, v7.1.3 RPDU2, v2.5.0.6 RPDU | PowerNet 4.5.2 | |
Schneider Electric | Rack PDU | Switched Rack PDU Series (Note: The standalone and daisy chained PDUs are both supported.) | 9XXX | v3.0 NMC3, v2.5.0.6 RPDU | PowerNet 4.5.2 | |
Schneider Electric | Rack PDU | Switched and Metered (Note: The standalone and daisy chained PDUs are both supported.) | 10XXX | v2.0.6.7, v2.0.6.5 NetShelter | apc_cpdu_V1_4 | |
Schneider Electric | Netbotz | Probe | Netbotz 450 series | v4.6.4 & newer | ||
Schneider Electric | UPS | Uninterruptible power supply | backUPS, Smart-UPS series, Smart-UPS X series, Floor UPS families, GVSUPS100KG, Symmetra LX series | 520.2000.D Symmetra | PowerNet 4.5.2 | |
ServerTech (Legrand) | Rack PDU | POPS, Switched, and Smart series, CDUs and Sentry3 and 4 | All models in each CDU series | 6.0, 7.0, 8.0(Recommended v7.0m firmware or newer) | Sentry3_20160125, Sentry4_20160921 | Optional, if no proxy index specified, the plugin assigns a value of 1. If specified cannot be 0. If a proxy index is given it will discover that one specifically and all children. |
Panduit/Unite/Sinetica | Rack PDU | Hawk-I Controller Unit & PDUs | Required, must be greater than 0 | |||
Tripp Lite | Rack PDU | PDU3VN, PDU3VSR, PDUMH20HVATNET | ||||
Starline (Legrand) | PDU / Rack PDU | Overhead Power Distribution | M40 series, V40 series, M50 series, V50 series Complete model list here | 4.07 | UEC_v27 | M type meters will be discovered using a proxy index of 1. Null proxy index 0 will not be usedV type meters will take a proxy index of 1 up to the maximum outlet count.Proxy Index 1 will represent Outlet 1Proxy Index 2 will represent Outlet 2, etcRead and Write community strings must be the same |